Separate Amplifier Type Pressure SensorAP-40 series

AP-40R

Amplifier Unit NPN

[Discontinued model]

This model has been discontinued.

Recommended Replaceable Products
To contact us:

SPECIFICATIONS

Select Language

Model

AP-40R

Output

NPN output

Display

3 1/2-digit, 2-colour, 7-segment LED (Character height: 11 mm ), Display cycle: 5 times/sec.

Detectable pressure range

-15% to +110% of F.S.

Display resolution

AP-41

0.1 kPa, 1 mmHg, 0.1 inchHg, 0.001 bar*1

AP-41M

AP-43

0.001 MPa, 0.01 kgf/cm20.2 PSI, 0.01 bar*1

AP-44

0.2 kPa, 2 mmHg, 0.1 inchHg, 0.002bar*1

AP-48

Response time (chattering
prevention function)

2.5/5/100/500 msec

Zero-shift input

No-voltage input (without contacts, with contacts), input time: 20 ms or more (RA and ZA only)

Control output

100 mA max. (40 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C. selectable)

Temperature fluctuation for display

±1.0% max. of F.S.

Rated pressure

-15% to +110% of F.S.

Mounting

With supplied mounting bracket (2 types) or optional panel mounting bracket *2

Current consumption

105 mA (12 V), 55 mA (24 V) (including sensor head)

Power supply

12 to 24 VDC ±10%, Ripple (p-p): 10% max.

Environmental
resistance

Ambient temperature

0 to +50°C (no freezing)

Ambient humidity

35 to 85% RH (No condensation)

Shock resistance

100 m/s2 in X, Y, and Z directions, 3 times respectively

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectively

Material

Front case: polyamide, front panel sheet: PET, rear case: polysulfone, cable: oil-proof cabtyre cable

Weight

80 g (including 2 m cable) (28 g without cable)

*1 The values are as shown in the following table during AP-40R zero shift focus mode.
*2 Two types of panel mounting brackets are available: OP-31357 (black) and OP-32908 (gray).