Heavy Duty Type Digital Pressure SensorsGP-M series


Main Unit, Positive-pressure Type, 2.5 MPa


Select Language



Rated pressure

-0.1 to +2.5 MPa
(-1 to +25 bar)

Possible display range

-0.360 to +2.760 MPa
(-3.60 to +27.60 bar)

Zero-cut pressure value

±0.5% of F.S.

Allowable pressure

10 MPa (100 bar)

Burst pressure

35 MPa (350 bar)

Display resolution

0.001 MPa (0.01 bar)

Fluid type

Gas or liquid that will not corrode the liquid contact part

Type of pressure

Gage pressure


±1.0% of F.S. or less*1


±0.3% of F.S. or less*2

Temperature characteristics

±0.6% of F.S./10°C

Connection diameter

G3/4 (Changes to the R male 1/8, R male 1/4, R male 3/8, G female 1/4, NPT male 1/8, and NPT male 1/4 option adapters are available.)

Box rotation angle

Maximum 330°

Medium temperature

-20 to +100°C (no freezing/condensation)*3

Power supply voltage

10-30 VDC, Ripple (P-P): 10% max, Class 2 or LPS

Current consumption

50 mA or less (when 24 V: 32 mA or less, when 12 V: 48 mA or less. Not including load)*4

Display method

4 column, digital LED, red/Vertical inversion display possible

Operation display light

Operation indicator (output 1) (orange), Operation indicator (output 2) (orange)


During hysteresis mode: variable (Difference between switch-on point and switch-off point is hysteresis)
During window mode: fixed (0.5% of F.S.)


Control output

Selectable from 3 to 5000 ms

Analogue output

As above + 2 ms (90% response)


Output 1 control output

NPN/PNP open collector (Selectable), Max. 250 mA (30 V max)
Main unit residual voltage 1 V max, N.O./N.C. selectable

Output 2
replacement type

Control output

Analogue output

4-20 mA, maximum load resistance 500 Ω (When the electric voltage is more than 20 V)*5


Ambient temperature

-20 to +80°C (no freezing/condensation)

Relative humidity

35 to 85% RH (No condensation)


IEC60068-2-6 20 G (10 to 2000 Hz, 2 hours each in the X, Y, and Z axes)


IEC60068-2-27 50 G (11 ms, 3 times for each of X, Y and Z axis)

Enclosure rating




Pressure port: SUSXM7, Diaphragm pressure port: Al2O3 (Alumina), O ring: FKM

Other parts

Housing metal portion: SUS304, SUS303, Housing plastic portion: PPSU, Air hole: PTFE, nickel-plated brass.

Applicable cable

M12 connector 4 pin


App. 150 g

*1 This is the value when considering linearity + hysterisis + repeatability in a stable environment of 23°C.
*2 The repeatability, based on consistent conditions, is the difference in the detection points at the time of fluctuations in the repetition.
*3 When the temperature of the piping exceeds 80°C, do not connect the cable.
*4 Consumption current including output is 0.6 A and under.
*5 The maximum load resistance R will be the values below in response to the electric voltage E. When 10-23V: R = {38 x (E-10) + 128} Ω When 23-30V: R = 622 Ω