Digital Fibre Optic SensorsFS-N series (FS-neo)

FS-N14N

Fibre Amplifier, Cable Type, Expansion Unit, NPN

SPECIFICATIONS

Select Language

Model

FS-N14N

Type

High functionality 2 output
Cable

Output

NPN

Main unit/Expansion unit

Expansion unit

Control output

2
NPN open collector 24 V; 1 output max: 100 mA or less; 2 output total: 100 mA or less (used stand-alone)/20 mA or less (multiple connections); residual voltage 1 V or less

Monitor output (1-5 V)

-

External input

1
Input time 2 ms (ON)/20 ms (OFF) or more (25 ms or more (ON/OFF) when external calibration is selected.)

Response time

50 μs (HIGH SPEED)/250 μs (FINE)/500 μs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA)

Multiple connections to Expansion units

Up to 16 units can be connected total (two output type is treated as two units)

Light source

Red, 4-element LED

APC

ON/OFF switchable (Factory setting: OFF)

Number of interference prevention units

0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA
(When set to double, the number of interference-prevention units will be doubled.)

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current Consumption

Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1
Eco on mode: 800 mW or less (32 mA max. at 24 V, 39 mA max. at 12 V)*1
Eco Full mode: 470 mW or less (19 mA max. at 24 V, 23 mA max. at 12 V)

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less

Ambient temperature

-20 to +55 °C (No freezing)*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Both main unit and expansion unit housing material: Polycarbonate

Weight

Approx. 70 g

*1 Increases 100 mW (4.0 mA) for High Speed mode
*2 One or two more units connected: -20 to +55 °C; 3 to 10 more units connected: -20 to +50 °C; 11 to 16 more units connected: -20 to +45 °C. When using 2-outputs, one unit is counted as two units. All temperature regulations are for when the unit is mounted on a DIN rail and installed on metal sheeting.