Manual-Calibration Fibreoptic SensorFS-V/T/M series (FS01)

FS-R3

Terminal Block Unit

[Discontinued model]

This model has been discontinued.

To contact us:

SPECIFICATIONS

Select Language

Model

FS-R3

Response time

350 µs to 1 ms *1

Indicator lamp

Red LED

Timer function

Number of inputs

2

Input signal

NPN/PNP non-voltage input (contact,solid-state) switching

Output mode

N.O./N.C. (selectable)

Rating

Power voltage

12 to 24 VDC ±5%, ripple (P-P): 5% max. *2

Current consumption

50 mA or less, plus current consumed by connected sensor
(100 mA max.)

Environmental resistance

Operating ambient temperature

-10 to +50°C, No condensation *3

Operating ambient humidity

35 to 85% RH (No condensation)

Vibration

10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours

Shock resistance

500 m/s2 in X, Y and Z directions, 3 times respectively

Case material

Polycarbonate

Weight

Approx 30 g

*1 The response speed varies depending on the number of expansion units connected.
*2 Change the supply voltage to meet the requirement of the input device (PLC, etc.).
*3 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
1 to 5 Units: -10 to +50°C, 6 to 8 Units: -10 to +45°C.