Heavy-duty Photoelectric SensorsPX series


Amplifier Unit, Cable Type, PNP


Select Language




Cable type



Response time

500 μs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA)

Output selection


Indicator lamp

- Operation indicator:Red LED x 2, DSC orange LED x 1
- Dual digital monitor:Dual 7-segment display
[Preset value (4-digit green LED) and current value (4-digit red LED) illuminated together,
current value range:0 to 65504, excess gain:0 P to 999 P]
- Hold function:Possible to display both peak and bottom hold values. Selectable from 5 variations.
- Bar LED monitor [Excess gain displayed (85% to 115% in 7 steps)]
- Scaling display

Detection mode

Light intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor]

Shift function

Variable between –1999 and 9999

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shot
Timer duration selectable:1 ms to 9999 ms
Maximum error against the setting value:10% max.

Control output

PNP open-collector 30 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max.

External input

Input time 2 ms (ON)/20 ms (OFF) min.

Interference prevention

Up to 4 units (in all power modes)*1


Power voltage

12 to 24 VDC ripple (P-P) 10% max. Class 2*2

Power consumption

Standard mode:50 mA max. at 24 V/55 mA max. at 12 V
Power saving mode:40 mA max. at 24 V/45 mA max. at 12 V

Environmental resistance

Enclosure rating


Operating ambient temperature

-10 to +55°C (14 to 131°F) (No freezing)*3

Operating ambient humidity

35 to 85% RH (No condensation)


10 to 55 Hz double amplitude 1.5 mm 2 hours each in X, Y and Z axis

Case material

Housing:PBT, display:PSU, display cover/connector cover:SUS304, radiator plate:SUS304, gasket:NBR


Approx. 100 g (Including cable)

*1 The received light intensity may vary somewhat when the sensor head's cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affected
somewhat when using multiple units installed adjacent to each other. Fine-tune the sensitivity (increase the setting) for adjacent layouts.
*2 Use a 24 VDC power voltage when using a head light transmitting cable of 3 m or more (PX-H71/H71TZ) or 10 m or more (PX-H72).
*3 When using multiple units connected adjacently, the ambient temperature varies with the conditions below.
2 to 4 Units:-10 to +50°C, 5 to 17 Units:-10 to +45°C.