Inductive Gauging SensorAS series

AS-440-01U

Amplifier Unit

SPECIFICATIONS

Select Language

Model

AS-440-01U

Type

General-use amplifier unit

Sensor head

AH-305

Shape

Cylindrical, diameter: 5.4

Measuring range

0 to 1mm

Analogue output voltage

Output voltage

0 to 1V

Impedance

100 Ω

Resolution

0.1% of F.S.

Linearity

±1% of F.S.

Response

3.3 kHz (-3 dB)

Temperature
fluctuation

Sensor head

0.03% of F.S./°C*1

Temperature characteristics

Amplifier unit

0.05% of F.S./°C*1

Rating

Power voltage

110/120/220/240 VAC ±10%, 50/60 Hz

Power consumption

5VA

Environmentalresistance

Enclosure rating

Sensor head

IP67

Operating ambient temperature

-10 to +60°C, No condensation

Amplifier unit

0 to +50°C

Environmental resistance

Operating ambient humidity

35 to 85%RH (no condensation)

Vibration

10 to 55 Hz, 1.5 mm, double amplitude, 2 hours in each of X, Y, and Z directions

Weight

Sensor head

Approx 45 g

Weight (including cord)

Amplifier unit

Approx 320g

*1 When the distance between the sensor head and the target is within 50% of the measurement range.