High-performance Micro Static Eliminator

SJ-M series

Select Language

Model

SJ-M200

SJ-M020

SJ-M020(1.2M)

SJ-M020(0.6M)

SJ-M020G

SJ-M020G(1.2M)

SJ-M020G(0.6M)

Type

Controller

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

0.5 sec max. *1

Ion balance

±15 V *2

Air purge supplied pressure

0.001 to 0.5 MPa *3

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open c ollector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Rating

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Operating ambient temperature

0 to +40°C

0 to 80°C*4*5

Operating ambient humidity

35 to 65% (No condensation) *3

Weight

Approx 300 g

Approx 600 g

Approx 540 g

Approx 480 g

Approx 600 g

Approx 540 g

Approx 480 g

*1 At installation distance 50 mm, air flow 60 Nl/min (ambient temperature 20 to 30°C, relative humidity 40 to 60%)
*2 At installation distance 50 mm, air flow 20 Nl/min (ambient temperature 20 to 30°C, relative humidity 40 to 60%)
*3 Contact KEYENCE for information about derating for humidity and pressure when the ambient temperature above 35°C. Use clean, dry air with a dew point of -20°C or less for the supplied fluid. Also, the
minimum air flow amount varies according to the nozzle. Contact KEYENCE for information about each nozzle.
*4 Use a supplied fluid with a temperature of 40°C or less.
*5 Only for the pressure cable. Other parts should be used with an ambient temperature of 0 to 40°C.

Model

SJ-M300

SJ-M030

SJ-M030C

SJ-M030G

SJ-M030V

SJ-M030VC

Type

Controller

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

±30 V*1

Ion balance

Air purge supplied pressure

0.2 MPa max.

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open c ollector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Effective length

164 mm (SJ-M030,SJ-M030C,SJ-M030G,SJ-M030V,SJ-M030VC),324 mm (SJ-M070,SJ-M070C,SJ-M070G,SJ-M070V,SJ-M070VC)

164 mm

Total length

220 mm (SJ-M030,SJ-M030C,SJ-M030G,SJ-M030V,SJ-M030VC),380 mm (SJ-M070,SJ-M070C,SJ-M070G,SJ-M070V,SJ-M070VC)

220 mm

Rating

Rating input

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Operating ambient temperature

0 to +40°C

Operating ambient humidity

35 to 65% RH (No condensation)

Weight

Approx 300 g

Approx 600 g

*1 Please make an inquiry as to the measurement condition.

Model

SJ-M300

SJ-M070

SJ-M070C

SJ-M070G

SJ-M070V

SJ-M070VC

Type

Controller

Head

Voltage application method

Pulse AC method

Applied voltage

±5.5 kV

Rated output voltage

±6 kV

Ion balance control method

I.C.C. method

Static elimination time

±30 V*1

Ion balance

Air purge supplied pressure

0.2 MPa max.

Control input

Static elimination stop input

Non-voltage input

Control output

Alarm output

NPN open c ollector 100 mA (40 V or less)

Ion level alarm output

Condition alarm output

Effective length

164 mm (SJ-M030,SJ-M030C,SJ-M030G,SJ-M030V,SJ-M030VC),324 mm (SJ-M070,SJ-M070C,SJ-M070G,SJ-M070V,SJ-M070VC)

324 mm

Total length

220 mm (SJ-M030,SJ-M030C,SJ-M030G,SJ-M030V,SJ-M030VC),380 mm (SJ-M070,SJ-M070C,SJ-M070G,SJ-M070V,SJ-M070VC)

380 mm

Rating

Rating input

Power voltage

24 VDC ±10%

Current consumption

450 mA max.

Environmental resistance

Operating ambient temperature

0 to +40°C

Operating ambient humidity

35 to 65% RH (No condensation)

Weight

Approx 300 g

Approx 720 g

*1 Please make an inquiry as to the measurement condition.

For visitors who viewed this page