Colour LCD Monitor

CA-M series

Select Language

Model

CA-MP120T*1*2

CA-MP120*3*2

Display panel

No. of dots

1024 (W) x 768 (H) dots or 800 (W) x 600 (H) dots

Active display area

245 (W)×184 (H)mm

Structure

Panel-mount type Front face is IP65 rated when panel mounted

Backlight

Operation life

Approx 100,000 hours
(When installed in an upright position
under 25°C)

Input/Output

Input signal

Analog RGB signal (0.7 Vp-p,
75 Ω), Horizontal/vertical
synchronization signal

Input signal mode

1024 (W) x 768 (H),
Vertical frequency: 60 Hz or
800 (W) x 600 (H),
Vertical frequency: 60 Hz

Connector

High-density D-sub 15-pin female (3-way, inch screw)

Touch panel connector

D-sub 9-pin male (2-way, inch screw)

Console connector

Connector for RJ45 use

Rating

Power voltage

24 VDC ±10%

Current consumption

1 A max.

Power voltage

24 VDC ±10%

Current consumption

1 A max.

Environmental
resistance

Ambient temperature

0 to +40°C

Operating Ambient humidity

35 to 85%RH

Weight

Approx 2300 g

*1 Options for CA-MP120T/CA-MP120 Monitor mounting stand: OP-87262
Options for CA-MP120T
For XG-7000/XG-8000/CV-X200: OP-87264 (Touch panel modular RS-232C cable 3 m), OP-87265 (Touch panel modular RS-232C cable 10 m)
For XG-8000/CV-X200: OP-87258 (Touch panel RS-232C cable 3 m), OP-87259 (Touch panel RS-232C cable 10 m)
Screen protector: OP-87263
Handheld controller junction cable: OP-87260 (Handheld controller junction cable 3 m), OP-87261 (Handheld controller junction cable 10 m)
*2 Use a junction cable if the handheld controller is inserted into the slot at the front of the touch panel.
*3 Options for CA-MP120T/CA-MP120 Monitor mounting stand: OP-87262
Options for CA-MP120T
For XG-7000: OP-87264 (Touch panel modular RS-232C cable 3 m), OP-87265 (Touch panel modular RS-232C cable 10 m)
For XG-8000: OP-87258 (Touch panel RS-232C cable 3 m), OP-87259 (Touch panel RS-232C cable 10 m)
Screen protector: OP-87263
Handheld controller junction cable: OP-87260 (Handheld controller junction cable 3 m), OP-87261 (Handheld controller junction cable 10 m)

Model

CA-MP81

Display panel

Display colour

a-Si, TFT active matrix method

262144

No. of dots

800 (W) x 600 (H) dots

Active display area

170.4 mm (W) x 127.8 mm (H)

Backlight

Method

One-way cold cathode fluorescent tube

Structure

Panel-mount type, Only the front face is dust-proof and splash-proof equivalent to IP65f.

Backlight

Operation life

Approx. 50,000 hours (average)
(When installed in an upright position under 25°C )

Input/Output

Input signal

Analog RGB signal (0.7 Vp-p,
75 Ω), Horizontal/vertical
synchronization signal

Input signal mode

800 (W) x 600 (H),
Vertical frequency: 60 Hz

Connector

High-density D-sub 15-pin female (3-way, inch screw)

Touch panel connector

Console connector

Rating

Power voltage

24 VDC ±10%

Current consumption

1 A max.

Environmental
resistance

Ambient temperature

0 to +40°C, No freezing

Operating Ambient humidity

35 to 85%, No condensation

Weight

Approx 1250 g

Model

CA-U4

Type

24 VDC Power supply

Input conditions

Rated input voltage

85 to 264 VAC , 47 to 63Hz , 110 to 370 VDC*1

Inputconditions

Efficiency

82% (100 VAC)/85% (200 VAC)typ. (with 100% load)

Input conditions

Rated input current

2.2 A or less (100 VAC)/1.1 A or less (1.1 A or less)

Output conditions

Rated output voltage

24 VDC

Rated output current

6.5A

Protection

Overvoltage protection

Constant current voltage limiting. Automatic reset 7.9 A min.

Activates at 26.4 V or more. Voltage interruption method,
recovers when input is applied again.*2

Applicable standards

Safety standards

UL : UL508、UL60950-1
C-UL : CSA C22.2 No.14-M95, CSA C22.2 No.60950-1-03
EN : EN60950-1、EN50178
IEC : IEC60950-1

EMC standard

FCC Part15B Class A, EN55011 Class A, EN61000-6-2

Limits for harmonic current emissions

EN61000-3-2

Environmental resistance

Ambient temperature for storage

-20 to 70°C, No freezing

Ambient temperature

-10 to +55°C (no freezing)

Ambient humidity

25 to 85% RH (No condensation)

Weight

Approx 700 g

*1 The rated input voltage and rated frequency when applying for safety standards are 100 to 240 VAC, 50/60 Hz.
*2 To recover, turn off the input power supply, leave it off for 1 minute or more, and then turn it on again.