Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          CMOS Multi-Function Analogue Laser Sensor

          IL series

          Select Language

          Model

          IL-030

          IL-065

          IL-100

          IL-300

          IL-600

          IL-2000*6

          Reference distance

          30 mm

          65 mm

          100 mm

          300 mm

          600 mm

          2000 mm

          Measurement range

          20 to 45 mm

          55 to 105 mm

          75 to 130 mm

          160 to 450 mm

          200 to 1000 mm

          1000 to 3500 mm

          Light source

          Type

          Red semiconductor laser, wavelength: 655 nm (visible light)

          Red semiconductor laser, wavelength: 655 nm (visible light)

          Laser class

          Class 1 (FDA (CDRH) Part1040.10)*1
          Class 1 (IEC 60825-1)

          Class 2 (FDA (CDRH) Part1040.10)*1
          Class 2 (IEC 60825-1)

          Class 2 laser product (FDA (CDRH) Part 1040.10,*7 IEC 60825-1)

          Output

          220 µW

          560 µW

          Spot diameter (at standard distance)

          Approx. 200 x 750 µm

          Approx. 550 x 1,750 µm

          Approx. 400 x 1,350 µm

          Approx. ø0.5 mm

          Approx. ø1.6 mm

          Approx. 1,400 x 7,000 µm

          Linearity

          ±0.1% of F.S. (25 mm to 35 mm)*2*3

          ±0.1% of F.S. (55 mm to 75 mm)*2*3

          ±0.15% of F.S. (80 mm to 120 mm)*2*3

          ±0.25% of F.S. (160 mm to 440 mm)*2*3

          ±0.25% of F.S. (200 to 600 mm)*2*3
          ±0.5% of F.S. (200 to 1000 mm)*2*3

          ±0.16% of F.S.
          (When used under
          1000 to 3500 mm)*8

          Repeatability

          1 µm*4

          2 µm*4

          4 µm*4

          30 µm*4

          50 µm*4

          100 µm*9

          Sampling rate

          0.33/1/2/5 ms (4 levels available)

          0.33/1/2/5 ms (Variable to 4 levels)

          Operation status indicators

          Laser emission warning indicator: Green LED, Analogue range indicator: Orange LED, Reference distance indicator: Red/Green LED

          Laser emission warning indicator: green LED, Analog range indicator: orange LED, Reference distance indicator: red/green LED

          Temperature characteristics

          0.05% of F.S./°C*3

          0.06% of F.S./°C*3

          0.08% of F.S./°C*3

          0.016% of F.S./°C*10

          Environmental resistance

          Enclosure rating

          IP67

          Pollution degree

          3

          Ambient light

          Incandescent lamp: 5,000 lux*5

          Incandescent lamp: 7,500 lux*5

          Incandescent lamp: 5,000 lux*5

          Incandescent lamp: 10,000 lux*5

          Ambient temperature

          -10 to +50 °C (No condensation or freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Material

          Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

          Housing material: PBT, Metal: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

          Weight

          Approx. 60 g

          Approx. 75 g

          Approx. 135 g

          Approx. 350 g

          *1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice No.50.
          *2 Value when measuring the KEYENCE standard target (white diffuse object).
          *3 F.S. of each model is as follows. IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm
          *4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms.
          *5 Value when the sampling rate is set to 2 ms or 5 ms.
          *6 Amplifiers purchased before August 8th, 2012 cannot be used.
          *7 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA (CDRH) Laser Notice No. 50.
          *8 Value when measuring the KEYENCE standard target (white diffuse object). F.S. for each model is as follows: IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm
          *9 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 16. For the IL-300/IL-600, the sampling rate is 2 ms.
          *10 F.S. for each model is as follows: IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm

          Amplifier

          Model

          IL-1000

          IL-1500

          IL-1050

          IL-1550

          Type

          DIN-rail mount

          Panel mount

          DIN-rail mount

          Panel mount

          Main unit/Expansion unit

          Main unit

          Expansion unit

          Head compatibility

          Compatible

          Display

          Minimum
          displayable unit

          IL-S025/IL-030: 1 µm, IL-S065/IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm

          Display range

          IL-S025/IL-030/IL-S065/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable),
          IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable)

          Display rate

          Approx. 10 times/sec.

          Analogue voltage output

          ±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 Ω*1

          None

          Analogue current output

          4 to 20 mA Maximum load resistance of 350 Ω*1

          Control input

          Bank switch input

          Non-voltage input*2

          Zero-shift input

          Stop emission input

          Timing input

          Reset input

          Control output

          Judgment output

          Open collector output (NPN, PNP changeover possible/N.O., N.C. changeover possible)*3

          Alarm output

          Open collector output (NPN, PNP changeover possible/N.C.)*3

          Current

          Power voltage

          10 to 30 VDC ripple (P-P) 10% included, Class 2*4

          Supplied by main unit*4

          Power consumption

          2300 mW or less (at 30 V: 77 mA or less)

          2500 mW or less (at 30 V: 84 mA or less)

          2000 mW or less (at 30 V: 67 mA or less)

          2200 mW or less (at 30 V: 74 mA or less)

          Environmental resistance

          Pollution degree

          2

          Ambient temperature

          -10 to +50 °C (No condensation or freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Material

          Case / Front sheet: Polycarbonate; Key tops: Polyacetel; Cable: PVC

          Weight

          Approx. 150 g (including attachments)

          Approx. 170 g (including attachments)

          Approx. 140 g (including attachments)

          Approx. 160 g (including attachments)

          *1 Select and use one of ±5 V, 1 to 5 V, 0 to 5 V or 4 to 20 mA.
          *2 Assign an input of your choice to the 4 external input lines before using.
          *3 The NPN open collector rated output is: 50 mA max./ch (20 mA when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit)
          The PNP open collector rated output is: 50 mA max./ch (20 mA/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit)
          *4 If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V.

          Measurement Library