Amplifier: NPN

Model

FS-T1

FS-T2

FS-M1

FS-M2

FS-M0

Type

Main unit

1-line expansion unit

Main unit

1-line expansion unit

0-line expansion unit

Output

NPN

-

Light source

Red LED

Sensitivity adjustment/Mode selection

Button

8-turn trimmer (with indicator), FINE/TURBO (switch-selectable)

Response time

250 µs

250 µs (FINE) /500 µs (TURBO)

410 µs to 1.2 ms*6

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output indicator: Red LED, Stable operation indicator: Green LED Calibration indicator: Orange LED

Output: Red LED
Stable operation: Green LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

Input

Non-voltage input (contact, solid state)

Control output

NPN: 100 mA (40 V) max.
Residual voltage: 1 V max.*1

Stability output

NPN open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max.*2

Protection circuit

Reversed polarity protection, Overcurrent protection, Surge absorber

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units)*3

Mutual interference suppression

4

FINE : 4, TURBO/SUPER: 8

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*5

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*5

Current consumption

35 mA or less

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-10 to +55 °C (No freezing)*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Weight

Approx. 75 g

Approx. 40 g

Approx. 75 g

Approx. 40 g

Approx. 20 g

*1 La salida de alarma de interrupción de conexión no está disponible en ES-M2 (P).
*2 Only the FS-T1 and FS-M1 can provide stability outputs.
*3 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F)
*4 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended
*5 Power to the FS-T2/T0/M2/M0 is supplied through the FS-T1/M1/V1/V11/R0, PS-T1, LV-21A/11A or CZ-V1.
*6 The response speed varies depending on the number of expansion units connected.

Amplifier: PNP

Model

FS-T1P

FS-T2P

FS-M1P

FS-M2P

Type

Main unit

1-line expansion unit

Main unit

1-line expansion unit

Output

PNP

Light source

Red LED

Sensitivity adjustment/Mode selection

Button

8-turn trimmer (with indicator), FINE/TURBO (switch-selectable)

Response time

250 µs

250 µs (FINE) /500 µs (TURBO)

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output indicator: Red LED, Stable operation indicator: Green LED Calibration indicator: Orange LED

Output: Red LED
Stable operation: Green LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

Input

Non-voltage input (contact, solid state)

Control output

PNP open-collector 100 mA max. (40 VDC max.), Residual voltage: 1 V max.

Stability output

PNP open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max.*1

Protection circuit

Reversed polarity protection, Overcurrent protection, Surge absorber

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units)*2

Mutual interference suppression

4

FINE : 4, TURBO/SUPER: 8

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*4

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*4

Current consumption

35 mA or less

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-10 to +55 °C (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Accessories

Fittings

Fittings

Weight

Approx. 75 g

Approx. 40 g

Approx. 75 g

Approx. 40 g

*1 Only the FS-T1 and FS-M1 can provide stability outputs.
*2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F)
*3 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended
*4 Power to the FS-T2/T0/M2/M0 is supplied through the FS-T1/M1/V1/V11/R0, PS-T1, LV-21A/11A or CZ-V1.

Fibre Amplifier, Cable Type, Main Unit, NPN

Model

FS-T1G

Light source

Green LED

Response time

250 µs

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Orange LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

External calibration input
signal

Non-voltage input (contact, solid state)

Input

Control output

NPN: 100 mA (40 V) max.
Residual voltage: 1 V max.*1

Stability output

NPN open-collector: 50 mA max. (40 VDC max.), Residual voltage:1 V max.

Protection circuit

Reversed polarity protection, Overcurrent protection, Surge absorber

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

35 mA or less

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-10 to +55 °C (No freezing)*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Accessories

Fittings

Weight

Approx. 75 g

*1 La salida de alarma de interrupción de conexión no está disponible en ES-M2 (P).
*2 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended

Fibre Amplifier, Cable Type, Main Unit, NPN

Model

FS-M1H

Light source

Red LED

Sensitivity adjustment/Mode selection

8-turn trimmer (with indicator),
FINE/TURBO (switch-selectable)

Response time

20 µs (FINE) /50 µs (TURBO)

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output: Red LED
Stable operation: Green LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

Control output

NPN: 100 mA (40 V) max.
Residual voltage: 1 V max.*1

Stability output

NPN open-collector: 50 mA max. (40 VDC max.), Residual voltage:1 V max.

Protection circuit

Reversed polarity protection, Overcurrent protection, Surge absorber

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

35 mA or less

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-10 to +55 °C (No freezing)*2

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Accessories

Fittings

Weight

Approx. 75 g

*1 La salida de alarma de interrupción de conexión no está disponible en ES-M2 (P).
*2 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended

For visitors who viewed this page

    Fibre Unit Finder

    • Fibre Unit Finder

    Latest / Most Downloaded

      • Trade Shows and Exhibitions
      • eNews Subscribe

      Sensors