FS series
|
Model |
FS2-60 |
FS2-62 |
FS2-65 |
|||
|
Type |
Trimmer:Long detecting distance |
Trimmer:Ultra-long detecting distance |
Trimmer:High-speed response |
|||
|
Light source |
Red LED |
|||||
|
Sensitivity adjustment |
8-turn trimmer |
|||||
|
Response time |
250 µs |
500 µs |
50 µs |
|||
|
Operation mode |
LIGHT-ON/DARK-ON (switch-selectable) |
|||||
|
Indicator lamp |
Output: Red LED |
|||||
|
Timer function |
ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable) |
|||||
|
External calibration input signal |
― |
|||||
|
Buzzer mode |
Buzzer ON when control output turns ON/Buzzer ON when alarm output turns ON/Buzzer OFF (switch-selectable) |
|||||
|
Output |
NPN output |
|||||
|
Control output |
NPN open-collector 100 mA max. (40 V max.), Residual voltage 1 V max. |
|||||
|
Stability output |
NPN open-collector 50 mA max. (40 V max.), Residual voltage 1 V max. |
|||||
|
Protection circuit |
Reversed polarity protection, Overcurrent protection, Surge absorber |
|||||
|
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||||
|
Current consumption |
35 mA or less |
|||||
|
Environmental resistance |
Ambient light |
Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max. |
||||
|
Ambient temperature |
-10 to +55 °C (No freezing) |
|||||
|
Relative humidity |
35 to 85 % RH (No condensation) |
|||||
|
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
|||||
|
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||||
|
Material |
Polycarbonate |
|||||
|
Weight |
Approx. 61 g |
|||||
Downloads
For Your Support