Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          High Speed, High Precision, Wide Static Eliminator Blower

          SJ-F2000/5000 series

          Select Language

          Fastest & Highest-Precision Type

          Model

          SJ-F2500

          SJ-F5500

          Type

          300 mm type

          600 mm type

          Voltage application method

          Pulse AC method

          Applied voltage

          ±7000V

          Ion balance control method

          I.C.C.

          Ion balance

          ±5 V*1

          Static elimination time

          Approx. 0.6 sec*2

          Operating distance

          50 mm min.

          Maximum wind speed

          5.7 m/s*1

          Maximum air volume

          4.0 m3/min

          10.0 m3/min

          Ozone density

          0.005 ppm max.

          Power source input type

          KEYENCE AC Adaptor or
          DC option

          AC cord input

          Rating

          Power voltage

          24 VDC ±10 %

          100 to 240 VAC, 50/60 Hz

          Current consumption

          1.2 A

          Power consumption

          90 VA

          Environmental resistance

          Pollution degree

          2

          Overvoltage category

          II

          Ambient temperature

          0 to +50 °C

          Relative humidity

          35 to 65 % RH

          Weight

          Approx. 2 kg

          Approx. 5 kg

          *1 Measured at a distance of 300 mm from the front of the fan
          *2 Measured at a distance of 300 mm from the front of the fan and at maximum air volume

          Short/Medium Distance Limited Type

          Model

          SJ-F2000

          SJ-F5000

          SJ-F2010

          SJ-F5010

          Type

          300 mm type

          600 mm type

          300 mm type

          600 mm type

          Voltage application method

          Pulse AC method

          Applied voltage

          ±7000V

          Ion balance control method

          I.C.C.

          Ion balance

          ±5 V*1

          Static elimination time

          Approx. 1 sec*2

          Operating distance

          50 mm min.

          Maximum wind speed

          3.5 m/s*1

          Maximum air volume

          2.5 m3/min

          6.2 m3/min

          2.5 m3/min

          6.2 m3/min

          Ozone density

          0.005 ppm max.

          Power source input type

          KEYENCE AC Adaptor or DC option

          AC cord input

          Terminal block DC input

          Control input

          Static elimination stop input

          24 VDC input

          Control output

          Alarm/ Ion level alert/ Condition alert

          NPN open-collector

          100 mA (40 V max.)

          PNP open-collector

          100 mA (24 V ±10%)

          Rating

          Power voltage

          24 VDC ±10 %

          100 to 240 VAC, 50/60 Hz

          24 VDC ±10 %

          Current consumption

          0.9 A

          1.0 A

          1.9 A

          Power consumption

          65 VA

          Environmental resistance

          Pollution degree

          2

          Overvoltage category

          II

          Ambient temperature

          0 to +50 °C

          Relative humidity

          35 to 65 % RH

          Weight

          Approx. 2 kg

          Approx. 5 kg

          Approx. 2 kg

          Approx. 4 kg

          *1 Measured at a distance of 300 mm from the front of the fan
          *2 Measured at a distance of 300 mm from the front of the fan and at maximum air volume

          AC adapter

          Model

          SJ-U2

          Rating

          Rating input

          100 to 240 VAC (50/60 Hz)

          Rated output

          24 VDC 2.65 A

          Environmental resistance

          Ambient temperature

          0 to +35 °C

          Relative humidity

          20 to 80 % RH (No condensation)

          Weight

          Approx. 250 g

          Static Eliminators / Ionisers