Recent Searches
    Series ( results)
      Models ( results)
        Keywords
          1. Home
          2. Products
          3. Vision / Auto ID
          4. Auto ID Products
          5. AutoID Data Controller
          6. Specs

          AutoID Data Controller

          DV-90 series

          Select Language

          Model

          DV-90NE

          DV-90PE

          Display power

          English

          Applicable barcode reader

          SR-2000/1000/750/700/G100*1, BL-1300/700/600/180/N70RKE, HR-100*2

          Preset data

          Number of registrations

          900 max.

          Backup method

          Flash ROM (Rewritable: 100000 times)

          I/O terminal

          Input terminals

          Number of inputs

          4

          Input rating

          10 to 26 VDC, 10 mA, Class2

          Maximum OFF current

          1.0 mA

          Output terminals

          Number of outputs

          16

          Output

          NPN open-collector

          PNP open-collector

          Output rating

          30 VDC, 100 mA

          Leakage current (at OFF)

          0.1 mA or less

          Residual voltage (at ON)

          Less than 1 V

          DC output

          Number of inputs

          2

          Output rating

          24 VDC ±10%, Max. 250 mA

          Serial interface

          RS-232C port

          Communication method

          RS-232C compliant

          Synchronisation between the transmitter and receiver

          Asynchronous

          Communication speed

          600 to 115200bps

          Number of inputs

          2 (PORT1, PORT2)

          Data length

          7/8 bits

          Parity

          None/Even/Odd

          Stop bit length

          1/2 bits

          USB port

          Number of inputs

          1

          Communication method

          USB 2.0 (B type) (Communication speed fi xed to 115,200 bps)

          Baud rate

          Communication speed fixed to 115200 bps

          RS-232C port

          Power supply for the barcode reader

          5 VDC ±5%, Max. 1100 mA (at the ambient temperature of 0 to +40°C)
          Max. 850 mA (at the ambient temperature of 40 to +50°C)

          Power output

          Power for sensor

          24 VDC ±10%, Max. 250 mA

          Rating

          Power voltage

          24 VDC ±10 %

          Current consumption

          850 mA or less

          Environmental resistance

          Enclosure rating

          IP65

          Operating environment

          No dust or corrosive gas present

          Ambient temperature

          0 to +50 °C

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 0.3 mm, 55 to 500 Hz, 2 G

          Weight

          Approx. 360 g

          *1 To connect the SR-1000/750, the OP-87533 and the OP-87527/87528/87529 are required. To connect the SR-G100, SR-LR1,OP-27937 are required
          *2 To connect the HR-100, the HR-1C3RC/OP-87533 are required. To connect the HR-100B, HR-UC1/HR-1C3RB/OP-88046/OP-99012/OP-88081 are required

          Barcode Scanner Library

          • traceability solutions
          • Trade Shows and Exhibitions
          • eNews Subscribe

          More Series In Auto ID Products

          Types In Vision / Auto ID

          Back to top

          KEYENCE INTERNATIONAL (BELGIUM) NV/SA Bedrijvenlaan 5, 2800 Mechelen, Belgium
          Phone: +32 (0) 15 281 222
          Fax: +32 (0) 15 201 623
          E-mail: info@keyence.eu
          Career Opportunities: KEYENCE Career Site

          Vision / Auto ID