RC series
|
Model |
RC-14*1 |
RC-19*1 |
|||
|
Type |
1-level preset counter/timer, DC type |
||||
|
Operation method |
Addition, subtraction |
||||
|
Operation mode |
Over-count and auto-reset |
||||
|
Return method |
Manual, External, Automatic (auto-reset) |
||||
|
Display power |
7-segment LED |
||||
|
Number of digits |
6 (with zero suppress function) -99999 to 999999*2 |
4 (with zero suppress function) -999 to 9999*2 |
|||
|
Power off memory time |
Service life: Approx 10 years at 20°C |
||||
|
Mounting method |
Flush (panel) mounting, surface mounting, DIN-rail mounting*3 |
||||
|
Highest counting speed |
Contact input: 30 c/s, solid-state input: 5 kc/s (ON-OFF ratio 1:1) |
||||
|
Input signal |
Non-voltage input (contact or solid-state) (Count input, inhibit input, reset input) |
||||
|
Output |
Control output |
NPN, 100 mA max. (40 V max.) |
|||
|
Control output |
One-shot output time |
0.01 to 0.5 s (variable) |
|||
|
Solid-state |
Solid state output: 15 ms max. (when set to 30 c/s) |
||||
|
DC output |
― |
||||
|
Rating |
Power voltage |
12 to 24 VDC ±10 % |
|||
|
Power consumption |
― |
||||
|
Current consumption |
150 mA or less |
||||
|
Environmental resistance |
Insulation resistance |
100 MΩ min. |
|||
|
Noise resistance |
Square-wave noise by noise simulator: 2 kV p-p, 1 µs (across power terminals) |
||||
|
Environmental resistance |
Ambient temperature |
-10 to +50 °C (No freezing) |
|||
|
Relative humidity |
35 to 85 % RH (No condensation) |
||||
|
Withstand voltage |
1,000 VAC, 1 minute (across terminal and casing) |
||||
|
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
||||
|
Shock resistance |
100 m/s2, 3 times in each of the X, Y, and Z directions |
||||
|
Weight |
Approx. 120 g |
||||
|
*1 This product does not comply with CE marking. |
|||||
|
Model |
RC-16 |
|||
|
Type |
1-level preset counter, DC type |
|||
|
Function selection |
- |
|||
|
Operation method |
Addition, subtraction, addition and subtraction (phase difference) |
|||
|
Operation mode |
Over-count, auto-reset, comparator |
|||
|
Return method |
Manual, External, Automatic (auto-reset) |
|||
|
Display power |
7-segment LCD (character height: 8.5 mm) |
|||
|
Number of digits |
6 (with zero-suppress function) -99999 to 999999 |
|||
|
Power off memory time |
Service life: Approx 10 years at 20°C |
|||
|
Timer accuracy |
- |
|||
|
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount |
|||
|
Highest counting speed |
Contact input: 30 c/s, solid-state input: 1 kc/s (ON/OFF ratio: 1:1) |
|||
|
Input signal |
Non-voltage input (contact or solid-state) (Count input, inhibit input, reset input) |
|||
|
Output |
Control output |
Maximum NPN open-collector output: 100 mA (40 V or less), residual voltage: 1 V or less*1 |
||
|
Control output |
Solid-state |
Relay output: 20 ms or less (when set to 30 c/s), 5 ms or less (when set to 1 kc/s); |
||
|
DC output |
- |
|||
|
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
|
Power consumption |
- |
|||
|
Current consumption |
45 mA or less |
|||
|
Noise resistance |
Square-wave noise by noise simulator: 1.2 kVp-p, 1 µs (across power terminals) |
|||
|
Environmental resistance |
Ambient temperature |
-10 to +50 °C (No freezing) |
||
|
Relative humidity |
35 to 85 % RH (No condensation) |
|||
|
Weight |
Approx. 75 g |
|||
|
*1 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter. |
||||
Downloads
For Your Support