Specs Linear Cylinder Sensor CS-L series

Linear cylinder sensor Standard type C-shaped slot PNP M8 connector 30 mm to 75 mm

Model

CS-LC30PC

CS-LC40PC

CS-LC50PC

CS-LC60PC

CS-LC75PC

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

C-shaped slot *1

Cable type

PNP M8 connector *2

Cylinder sensor

Sensor size

30 mm

40 mm

50 mm

60 mm

75 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *3

Detection cycle

1 ms *4

Impact monitoring function

Available (PNP M8 connector type only)

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5

Network function

PNP output M8 connector (4-pin) only: IO-Link (Specification v1.1/COM3)

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 14 g

Approx. 15 g

Approx. 16 g

Approx. 17 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 Switching to NPN is possible when using a high-functionality amplifier.
*3 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*4 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*5 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*6 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type C-shaped slot PNP M8 connector 100 mm to 200 mm

Model

CS-LC100PC

CS-LC125PC

CS-LC150PC

CS-LC175PC

CS-LC200PC

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

C-shaped slot *1

Cable type

PNP M8 connector *2

Cylinder sensor

Sensor size

100 mm

125 mm

150 mm

175 mm

200 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *3

Detection cycle

1 ms *4

Impact monitoring function

Available (PNP M8 connector type only)

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5

Network function

PNP output M8 connector (4-pin) only: IO-Link (Specification v1.1/COM3)

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 18 g

Approx. 20 g

Approx. 21 g

Approx. 23 g

Approx. 24 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 Switching to NPN is possible when using a high-functionality amplifier.
*3 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*4 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*5 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*6 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type C-shaped slot PNP strand wire 30 mm to 75 mm

Model

CS-LC30P

CS-LC40P

CS-LC50P

CS-LC60P

CS-LC75P

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

C-shaped slot *1

Cable type

PNP strand wire

Cylinder sensor

Sensor size

30 mm

40 mm

50 mm

60 mm

75 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *2

Detection cycle

1 ms *3

Impact monitoring function

—

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4

Network function

—

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 31 g

Approx. 32 g

Approx. 33 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*3 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*4 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*5 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type C-shaped slot PNP strand wire 100 mm to 200 mm

Model

CS-LC100P

CS-LC125P

CS-LC150P

CS-LC175P

CS-LC200P

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

C-shaped slot *1

Cable type

PNP strand wire

Cylinder sensor

Sensor size

100 mm

125 mm

150 mm

175 mm

200 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *2

Detection cycle

1 ms *3

Impact monitoring function

—

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4

Network function

—

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 35 g

Approx. 36 g

Approx. 38 g

Approx. 39 g

Approx. 45 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*3 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*4 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*5 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type C-shaped slot NPN strand wire 30 mm to 75 mm

Model

CS-LC30N

CS-LC40N

CS-LC50N

CS-LC60N

CS-LC75N

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

C-shaped slot *1

Cable type

NPN strand wire

Cylinder sensor

Sensor size

30 mm

40 mm

50 mm

60 mm

75 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *2

Detection cycle

1 ms *3

Impact monitoring function

—

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4

Network function

—

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 31 g

Approx. 32 g

Approx. 33 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*3 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*4 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*5 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type C-shaped slot NPN strand wire 100 mm to 200 mm

Model

CS-LC100N

CS-LC125N

CS-LC150N

CS-LC175N

CS-LC200N

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

C-shaped slot *1

Cable type

NPN strand wire

Cylinder sensor

Sensor size

100 mm

125 mm

150 mm

175 mm

200 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *2

Detection cycle

1 ms *3

Impact monitoring function

—

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4

Network function

—

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 35 g

Approx. 36 g

Approx. 38 g

Approx. 39 g

Approx. 45 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*3 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*4 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*5 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type T-shaped slot PNP M8 connector 30 mm to 80 mm

Model

CS-LT30PC

CS-LT40PC

CS-LT50PC

CS-LT60PC

CS-LT80PC

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

T-shaped slot *1

Cable type

PNP M8 connector *2

Cylinder sensor

Sensor size

30 mm

40 mm

50 mm

60 mm

80 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *3

Detection cycle

1 ms *4

Impact monitoring function

Available (PNP M8 connector type only)

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5

Network function

PNP output M8 connector (4-pin) only: IO-Link (Specification v1.1/COM3)

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 14 g

Approx. 15 g

Approx. 16 g

Approx. 17 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 Switching to NPN is possible when using a high-functionality amplifier.
*3 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*4 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*5 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*6 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type T-shaped slot PNP M8 connector 100 mm to 200 mm

Model

CS-LT100PC

CS-LT125PC

CS-LT150PC

CS-LT175PC

CS-LT200PC

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

T-shaped slot *1

Cable type

PNP M8 connector *2

Cylinder sensor

Sensor size

100 mm

125 mm

150 mm

175 mm

200 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *3

Detection cycle

1 ms *4

Impact monitoring function

Available (PNP M8 connector type only)

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5

Network function

PNP output M8 connector (4-pin) only: IO-Link (Specification v1.1/COM3)

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 18 g

Approx. 20 g

Approx. 21 g

Approx. 23 g

Approx. 24 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 Switching to NPN is possible when using a high-functionality amplifier.
*3 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*4 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*5 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*6 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type T-shaped slot PNP strand wire 30 mm to 80 mm

Model

CS-LT30P

CS-LT40P

CS-LT50P

CS-LT60P

CS-LT80P

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

T-shaped slot *1

Cable type

PNP strand wire

Cylinder sensor

Sensor size

30 mm

40 mm

50 mm

60 mm

80 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *2

Detection cycle

1 ms *3

Impact monitoring function

—

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4

Network function

—

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 31 g

Approx. 32 g

Approx. 33 g

Approx. 34 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*3 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*4 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*5 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type T-shaped slot PNP strand wire 100 mm to 200 mm

Model

CS-LT100P

CS-LT125P

CS-LT150P

CS-LT175P

CS-LT200P

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

T-shaped slot *1

Cable type

PNP strand wire

Cylinder sensor

Sensor size

100 mm

125 mm

150 mm

175 mm

200 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *2

Detection cycle

1 ms *3

Impact monitoring function

—

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4

Network function

—

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 35 g

Approx. 36 g

Approx. 38 g

Approx. 39 g

Approx. 45 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*3 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*4 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*5 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type T-shaped slot NPN strand wire 30 mm to 80 mm

Model

CS-LT30N

CS-LT40N

CS-LT50N

CS-LT60N

CS-LT80N

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

T-shaped slot *1

Cable type

NPN strand wire

Cylinder sensor

Sensor size

30 mm

40 mm

50 mm

60 mm

80 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *2

Detection cycle

1 ms *3

Impact monitoring function

—

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4

Network function

—

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 31 g

Approx. 32 g

Approx. 33 g

Approx. 34 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*3 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*4 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*5 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Standard type T-shaped slot NPN strand wire 100 to mm 200 mm

Model

CS-LT100N

CS-LT125N

CS-LT150N

CS-LT175N

CS-LT200N

Image

Type

Sensor type

Linear cylinder sensor Standard type

Supported slot shape

T-shaped slot *1

Cable type

NPN strand wire

Cylinder sensor

Sensor size

100 mm

125 mm

150 mm

175 mm

200 mm

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *2

Detection cycle

1 ms *3

Impact monitoring function

—

Display method

Bar LED

Number of outputs

When using just the sensor

2

When connected to IO-Link or the SP-N/V Series

4

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4

Network function

—

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 35 g

Approx. 36 g

Approx. 38 g

Approx. 39 g

Approx. 45 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*3 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*4 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*5 Including load current: 136 mA or less.

Back to top

Linear cylinder sensor Dual type C-shaped slot/T-shaped slot

Model

CS-LDC30PC

CS-LDT30PC

Image

Type

Sensor type

Linear cylinder sensor Dual type

Supported slot shape

C-shaped slot *1

T-shaped slot *1

Cable type

PNP M8 connector *2

Cylinder sensor

Sensor size

30 mm × 2 heads

Detection length

Sensor size + 5 mm

Minimum detectable magnetic flux density

2 mT

Max. supported speed

3 m/s

Resolution

0.1 mm

Repeatability

±0.5 mm *3

Detection cycle

1 ms *4

Impact monitoring function

Available

Display method

Bar LED

Number of outputs

When using just the sensor

1 per head

When connected to IO-Link or the SP-N/V Series

4 per head

Control output

Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5

Network function

—

Power supply

Power voltage

18 to 30 VDC, ripple included, Class 2 or LPS

Power consumption

650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +60°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR

Weight

Approx. 28 g

*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing.
*2 Switching to NPN is possible when using a high-functionality amplifier.
*3 This value is guaranteed by KEYENCE inspection facilities. Measurement errors may occur depending on the installation environment, such as the cylinder used.
*4 The default response time is 3 ms. The response time can be set as fast as 2 ms when using a high-functionality amplifier, panel, or IO-Link. When used with a high-functionality amplifier, the cylinder response time increases by up to +11 ms. When used with a smart cushion valve, the time increases by up to +6 ms.
*5 Ensure the cable length is 30 m or less for the PNP M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*6 Including load current: 136 mA or less.

Back to top

High-functionality amplifier

Model

CS-LA1C

Image

Type

High-functionality amplifier

Number of connectable cylinder sensors

Max. 2 *1

Number of outputs

When using just the sensor

3

When using IO-Link

4 *2

Control output

PNP/NPN switchable, Open-collector output: 30 VDC or less, 100 mA total for 3 outputs, Residual voltage: 2.5 V or less

Network function

IO-Link (Specification v1.1/COM3)

Power supply

Power voltage

24 VDC -20 to +25%, ripple included, Class 2 or LPS *3

Power consumption

1.2 W
(50 mA or less at 24 V/62 mA or less at 19.2 V [high-functionality amplifier only; excluding load current]) *4

Environmental resistance

Enclosure rating

IP65/IP67

Protection circuit

Reverse polarity protection, Output overcurrent protection

Ambient temperature

-20 to +50°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

PBT SUS303

Weight

Approx. 20 g

*1 Y-shaped cable required to connect two devices.
*2 When using the dual type, connecting two units with a Y-shaped cable provides 4 outputs per head, for a total of 8 outputs.
*3 The total cable length of the cable between the cylinder sensor and the high-functionality amplifier and of the high-functionality amplifier power cable must be no more than 30 m. (When using IO-Link, the high-functionality amplifier power cable must be no more than 20 m.)
*4 Including load current and connected sensors: 230 mA or less.

Back to top