Smart cushion valve Middle type ø6 SP-CM6

SP-CM6 - Smart cushion valve Middle type ø6

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD / CAE

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

SP-CM6

Type

Smart cushion valve Middle type

Supported pipe diameter

Pipe outer diameter

ø6

Pipe material

Nylon, Polyurethane

Supported fluids

Air*1

Supported fluid temperature

-10 to +50°C

Operating pressure range

0.2 to 0.8 MPa

Pressure resistance

1.0 MPa

Maximum operating frequency

1 Hz

Flow rate characteristics

Before deceleration

380 L/min*2

After deceleration

90 L/min*2

Number of connectable cylinder sensors

1

Number of outputs

2

Control output

NPN/PNP switchable, Open-collector output: 30 VDC or less
100 mA max. total for 2 outputs, Residual voltage: 2.5 V or less

External input

Short-circuit current: 1.5 mA max.

Network function

IO-Link (Specification v1.1/COM3)

Power supply

Power voltage

24 VDC -20 to +25%, ripple included, Class 2 or LPS*3

Power consumption

1.2 W (50 mA or less at 24 V/62 mA or less at 19.2 V [smart cushion valve only; excluding load current])*4

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Protection circuit

Reverse polarity protection, Power supply surge protection, Output overcurrent protection

Ambient temperature

-10 to +50°C (no freezing)

Relative humidity

Up to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

100 m/s2 (10 G); 1000 times each for X, Y, and Z axes

Material

Flow path

Polyamide, Aluminium alloy, FKM, NBR, HNBR, POM

Non-flow path

Polyamide, Aluminium alloy, FKM, NBR, HNBR, SUS304, POM, PBT, PAR

Weight

Approx. 110 g

*1 If air with a low dew point is used as the operating fluid, deterioration of the lubrication characteristics inside the device may affect the reliability (service life) of the equipment.
*2 Measured values obtained using KEYENCE testing equipment ([before deceleration] upstream: 0.6 MPa, downstream 0.5 MPa; [after deceleration] upstream: 0.5 MPa, downstream: open to atmosphere). (Values have been converted to 20°C, atmospheric pressure.) Measurement errors may occur depending on the user environment.
*3 The total cable length of the cable between the cylinder sensor and the smart cushion valve and of the smart cushion valve power cable must be no more than 30 m. (When using IO-Link, the smart cushion valve power cable must be no more than 20 m.)
*4 Including load current: 196 mA or less

Data Sheet (PDF) Other Models