Safety Light Curtain
SL-V series
Main Unit, General-purpose Type, 14 Optical Axes SL-V14L
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | SL-V14L  | |||
Detection capability  | ø45 mm  | |||
Beam axis spacing/Lens diameter  | 40 mm/ø5 mm  | |||
Effective aperture angle  | Max. ±2.5 ° (When operating distance is 3 m or more)  | |||
Working distance  | 0.1 to 9 m  | |||
Response time (ms)  | ON→OFF  | 7.8*1  | ||
OFF→ON  | 47.8*1  | |||
Light source  | Infrared LED (850 nm)  | |||
Operation mode  | Turns on when no interruptions are present in the detection zone (excluding when the muting function is used)  | |||
OSSD output  | Output  | 2 outputs each for PNP and NPN. Can be changed by using the connector cable.  | ||
Max. l oad current  | 500 mA*2  | |||
Residual vol tage (during ON)  | Max. 2.5 V (with a cable length of 7 m)  | |||
Leakage current  | Max. 100 µA*3  | |||
Max. capacitive load  | 2.2 µF (with a load resistance of 100 Ω)  | |||
Load wiring resistance  | Max. 2.5 Ω*4  | |||
Non safety-rel atedoutput  | AUX  | Output with automatic PNP/NPN switching function, 50 mA max.  | ||
Interlock-reset-ready output  | ||||
Alarm output  | ||||
Clear/blocked output  | ||||
State information output 1, 2  | ||||
Muting lamp output  | Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected  | |||
Input  | EDM input  | Short-circuit current 10 mA  | ||
Wait input  | Short-circuit current 2.5 mA  | |||
Reset input  | ||||
Muting input 1, 2  | ||||
Override input  | ||||
Protection circuit  | Reverse current protection, short-circuit protection for each output, surge protection for each output  | |||
Approved standards  | EMC  | EMS  | IEC61496-1, EN61496-1, UL61496-1  | |
EMI  | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA  | |||
Safety  | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)  | |||
Rating  | Power voltage  | 24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less  | ||
Current consumption (mA)  | When the Centre indicator is ON  | Transmitter  | 74*6  | |
Receiver  | 76*6  | |||
When the Centre indicator is OFF  | Transmitter  | 68*6  | ||
Receiver  | ||||
Environmental resistance  | Enclosure rating  | IP65 (IEC60529)  | ||
Overvoltage category  | II  | |||
Ambient light  | Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max.  | |||
Operating ambient temperature  | -10 to +55 °C (No freezing)  | |||
Operating relative humidity  | 15 to 85 % RH (No condensation)  | |||
Storage temperature  | -25 to +60 °C (No freezing)  | |||
Storage relative humidity  | 15 to 95 % RH  | |||
Vibration resistance  | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions  | |||
Shock resistance  | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | |||
Material  | Main unit case  | Aluminium  | ||
Upper case/lower case  | Zinc die-cast  | |||
Front cover  | Polycarbonate, SUS304  | |||
Weight  | Transmitter  | 400 g  | ||
Receiver  | 415 g  | |||
*1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of theresponse times of al l the individual SL-V units, but the response time (OFF to ON) is the sameas that of a singl e SL-V unit.  | ||||