Linear Cylinder Sensor
CS-L series
Specs Linear Cylinder Sensor CS-L series
Linear cylinder sensor Standard type C-shaped slot PNP M8 connector 30 mm to 75 mm
|
Model |
CS-LC30PC |
CS-LC40PC |
CS-LC50PC |
CS-LC60PC |
CS-LC75PC |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
C-shaped slot *1 |
|||||||
|
Cable type |
PNP M8 connector *2 |
|||||||
|
Cylinder sensor |
Sensor size |
30 mm |
40 mm |
50 mm |
60 mm |
75 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *3 |
|||||||
|
Detection cycle |
1 ms *4 |
|||||||
|
Impact monitoring function |
Available (PNP M8 connector type only) |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5 |
|||||||
|
Network function |
PNP output M8 connector (4-pin) only: IO-Link (Specification v1.1/COM3) |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 14 g |
Approx. 15 g |
Approx. 16 g |
Approx. 17 g |
||||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type C-shaped slot PNP M8 connector 100 mm to 200 mm
|
Model |
CS-LC100PC |
CS-LC125PC |
CS-LC150PC |
CS-LC175PC |
CS-LC200PC |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
C-shaped slot *1 |
|||||||
|
Cable type |
PNP M8 connector *2 |
|||||||
|
Cylinder sensor |
Sensor size |
100 mm |
125 mm |
150 mm |
175 mm |
200 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *3 |
|||||||
|
Detection cycle |
1 ms *4 |
|||||||
|
Impact monitoring function |
Available (PNP M8 connector type only) |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5 |
|||||||
|
Network function |
PNP output M8 connector (4-pin) only: IO-Link (Specification v1.1/COM3) |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 18 g |
Approx. 20 g |
Approx. 21 g |
Approx. 23 g |
Approx. 24 g |
|||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type C-shaped slot PNP strand wire 30 mm to 75 mm
|
Model |
CS-LC30P |
CS-LC40P |
CS-LC50P |
CS-LC60P |
CS-LC75P |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
C-shaped slot *1 |
|||||||
|
Cable type |
PNP strand wire |
|||||||
|
Cylinder sensor |
Sensor size |
30 mm |
40 mm |
50 mm |
60 mm |
75 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *2 |
|||||||
|
Detection cycle |
1 ms *3 |
|||||||
|
Impact monitoring function |
— |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4 |
|||||||
|
Network function |
— |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 31 g |
Approx. 32 g |
Approx. 33 g |
|||||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type C-shaped slot PNP strand wire 100 mm to 200 mm
|
Model |
CS-LC100P |
CS-LC125P |
CS-LC150P |
CS-LC175P |
CS-LC200P |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
C-shaped slot *1 |
|||||||
|
Cable type |
PNP strand wire |
|||||||
|
Cylinder sensor |
Sensor size |
100 mm |
125 mm |
150 mm |
175 mm |
200 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *2 |
|||||||
|
Detection cycle |
1 ms *3 |
|||||||
|
Impact monitoring function |
— |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4 |
|||||||
|
Network function |
— |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 35 g |
Approx. 36 g |
Approx. 38 g |
Approx. 39 g |
Approx. 45 g |
|||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type C-shaped slot NPN strand wire 30 mm to 75 mm
|
Model |
CS-LC30N |
CS-LC40N |
CS-LC50N |
CS-LC60N |
CS-LC75N |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
C-shaped slot *1 |
|||||||
|
Cable type |
NPN strand wire |
|||||||
|
Cylinder sensor |
Sensor size |
30 mm |
40 mm |
50 mm |
60 mm |
75 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *2 |
|||||||
|
Detection cycle |
1 ms *3 |
|||||||
|
Impact monitoring function |
— |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4 |
|||||||
|
Network function |
— |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 31 g |
Approx. 32 g |
Approx. 33 g |
|||||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type C-shaped slot NPN strand wire 100 mm to 200 mm
|
Model |
CS-LC100N |
CS-LC125N |
CS-LC150N |
CS-LC175N |
CS-LC200N |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
C-shaped slot *1 |
|||||||
|
Cable type |
NPN strand wire |
|||||||
|
Cylinder sensor |
Sensor size |
100 mm |
125 mm |
150 mm |
175 mm |
200 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *2 |
|||||||
|
Detection cycle |
1 ms *3 |
|||||||
|
Impact monitoring function |
— |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4 |
|||||||
|
Network function |
— |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 35 g |
Approx. 36 g |
Approx. 38 g |
Approx. 39 g |
Approx. 45 g |
|||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type T-shaped slot PNP M8 connector 30 mm to 80 mm
|
Model |
CS-LT30PC |
CS-LT40PC |
CS-LT50PC |
CS-LT60PC |
CS-LT80PC |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
T-shaped slot *1 |
|||||||
|
Cable type |
PNP M8 connector *2 |
|||||||
|
Cylinder sensor |
Sensor size |
30 mm |
40 mm |
50 mm |
60 mm |
80 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *3 |
|||||||
|
Detection cycle |
1 ms *4 |
|||||||
|
Impact monitoring function |
Available (PNP M8 connector type only) |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5 |
|||||||
|
Network function |
PNP output M8 connector (4-pin) only: IO-Link (Specification v1.1/COM3) |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 14 g |
Approx. 15 g |
Approx. 16 g |
Approx. 17 g |
||||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type T-shaped slot PNP M8 connector 100 mm to 200 mm
|
Model |
CS-LT100PC |
CS-LT125PC |
CS-LT150PC |
CS-LT175PC |
CS-LT200PC |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
T-shaped slot *1 |
|||||||
|
Cable type |
PNP M8 connector *2 |
|||||||
|
Cylinder sensor |
Sensor size |
100 mm |
125 mm |
150 mm |
175 mm |
200 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *3 |
|||||||
|
Detection cycle |
1 ms *4 |
|||||||
|
Impact monitoring function |
Available (PNP M8 connector type only) |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5 |
|||||||
|
Network function |
PNP output M8 connector (4-pin) only: IO-Link (Specification v1.1/COM3) |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 18 g |
Approx. 20 g |
Approx. 21 g |
Approx. 23 g |
Approx. 24 g |
|||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type T-shaped slot PNP strand wire 30 mm to 80 mm
|
Model |
CS-LT30P |
CS-LT40P |
CS-LT50P |
CS-LT60P |
CS-LT80P |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
T-shaped slot *1 |
|||||||
|
Cable type |
PNP strand wire |
|||||||
|
Cylinder sensor |
Sensor size |
30 mm |
40 mm |
50 mm |
60 mm |
80 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *2 |
|||||||
|
Detection cycle |
1 ms *3 |
|||||||
|
Impact monitoring function |
— |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4 |
|||||||
|
Network function |
— |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 31 g |
Approx. 32 g |
Approx. 33 g |
Approx. 34 g |
||||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type T-shaped slot PNP strand wire 100 mm to 200 mm
|
Model |
CS-LT100P |
CS-LT125P |
CS-LT150P |
CS-LT175P |
CS-LT200P |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
T-shaped slot *1 |
|||||||
|
Cable type |
PNP strand wire |
|||||||
|
Cylinder sensor |
Sensor size |
100 mm |
125 mm |
150 mm |
175 mm |
200 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *2 |
|||||||
|
Detection cycle |
1 ms *3 |
|||||||
|
Impact monitoring function |
— |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4 |
|||||||
|
Network function |
— |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 35 g |
Approx. 36 g |
Approx. 38 g |
Approx. 39 g |
Approx. 45 g |
|||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type T-shaped slot NPN strand wire 30 mm to 80 mm
|
Model |
CS-LT30N |
CS-LT40N |
CS-LT50N |
CS-LT60N |
CS-LT80N |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
T-shaped slot *1 |
|||||||
|
Cable type |
NPN strand wire |
|||||||
|
Cylinder sensor |
Sensor size |
30 mm |
40 mm |
50 mm |
60 mm |
80 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *2 |
|||||||
|
Detection cycle |
1 ms *3 |
|||||||
|
Impact monitoring function |
— |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4 |
|||||||
|
Network function |
— |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 31 g |
Approx. 32 g |
Approx. 33 g |
Approx. 34 g |
||||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Standard type T-shaped slot NPN strand wire 100 to mm 200 mm
|
Model |
CS-LT100N |
CS-LT125N |
CS-LT150N |
CS-LT175N |
CS-LT200N |
|||
|
Image |
|
|
|
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Standard type |
||||||
|
Supported slot shape |
T-shaped slot *1 |
|||||||
|
Cable type |
NPN strand wire |
|||||||
|
Cylinder sensor |
Sensor size |
100 mm |
125 mm |
150 mm |
175 mm |
200 mm |
||
|
Detection length |
Sensor size + 5 mm |
|||||||
|
Minimum detectable magnetic flux density |
2 mT |
|||||||
|
Max. supported speed |
3 m/s |
|||||||
|
Resolution |
0.1 mm |
|||||||
|
Repeatability |
±0.5 mm *2 |
|||||||
|
Detection cycle |
1 ms *3 |
|||||||
|
Impact monitoring function |
— |
|||||||
|
Display method |
Bar LED |
|||||||
|
Number of outputs |
When using just the sensor |
2 |
||||||
|
When connected to IO-Link or the SP-N/V Series |
4 |
|||||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *4 |
|||||||
|
Network function |
— |
|||||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
||||||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *5 |
|||||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
||||||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
|||||||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
|||||||
|
Weight |
Approx. 35 g |
Approx. 36 g |
Approx. 38 g |
Approx. 39 g |
Approx. 45 g |
|||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
||||||||
Linear cylinder sensor Dual type C-shaped slot/T-shaped slot
|
Model |
CS-LDC30PC |
CS-LDT30PC |
|||
|
Image |
|
|
|||
|
Type |
Sensor type |
Linear cylinder sensor Dual type |
|||
|
Supported slot shape |
C-shaped slot *1 |
T-shaped slot *1 |
|||
|
Cable type |
PNP M8 connector *2 |
||||
|
Cylinder sensor |
Sensor size |
30 mm × 2 heads |
|||
|
Detection length |
Sensor size + 5 mm |
||||
|
Minimum detectable magnetic flux density |
2 mT |
||||
|
Max. supported speed |
3 m/s |
||||
|
Resolution |
0.1 mm |
||||
|
Repeatability |
±0.5 mm *3 |
||||
|
Detection cycle |
1 ms *4 |
||||
|
Impact monitoring function |
Available |
||||
|
Display method |
Bar LED |
||||
|
Number of outputs |
When using just the sensor |
1 per head |
|||
|
When connected to IO-Link or the SP-N/V Series |
4 per head |
||||
|
Control output |
Open-collector output: 30 VDC or less, 100 mA total for 2 outputs, Residual voltage: 2.5 V or less *5 |
||||
|
Network function |
— |
||||
|
Power supply |
Power voltage |
18 to 30 VDC, ripple included, Class 2 or LPS |
|||
|
Power consumption |
650 mW (27 mA or less at 24 V/36 mA or less at 18 V [excluding load current]) *6 |
||||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC 60529) |
|||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
||||
|
Ambient temperature |
-20 to +60°C (no freezing) |
||||
|
Relative humidity |
Up to 85% RH (no condensation) |
||||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
||||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
||||
|
Material |
Polyamide, PBT, POM, SUS303, Zinc nickel plating, NBR |
||||
|
Weight |
Approx. 28 g |
||||
|
*1 For cylinders other than C/T-shaped slot types, installation may be possible by using optional brackets (sold separately). The slot shape and size may vary depending on the cylinder manufacturer, cylinder type, and release date. Verify installation is possible before purchasing. |
|||||
High-functionality amplifier
|
Model |
CS-LA1C |
|||
|
Image |
|
|||
|
Type |
High-functionality amplifier |
|||
|
Number of connectable cylinder sensors |
Max. 2 *1 |
|||
|
Number of outputs |
When using just the sensor |
3 |
||
|
When using IO-Link |
4 *2 |
|||
|
Control output |
PNP/NPN switchable, Open-collector output: 30 VDC or less, 100 mA total for 3 outputs, Residual voltage: 2.5 V or less |
|||
|
Network function |
IO-Link (Specification v1.1/COM3) |
|||
|
Power supply |
Power voltage |
24 VDC -20 to +25%, ripple included, Class 2 or LPS *3 |
||
|
Power consumption |
1.2 W |
|||
|
Environmental resistance |
Enclosure rating |
IP65/IP67 |
||
|
Protection circuit |
Reverse polarity protection, Output overcurrent protection |
|||
|
Ambient temperature |
-20 to +50°C (no freezing) |
|||
|
Relative humidity |
Up to 85% RH (no condensation) |
|||
|
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
|
Shock resistance |
100 m/s2 (10 G); 1000 times each for X, Y, and Z axes |
|||
|
Material |
PBT SUS303 |
|||
|
Weight |
Approx. 20 g |
|||
|
*1 Y-shaped cable required to connect two devices. |
||||