CMOS Multi-Function Analogue Laser Sensor

IL series

Catalogues View Catalogue

Sensor heads IL-2000

IL-2000 - Sensor heads

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • CSA

Specifications

Model

IL-2000*1

Reference distance

2000 mm

Measurement range

1000 to 3500 mm

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 laser product (FDA (CDRH) Part 1040.10,*2 IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. 1,400 x 7,000 µm

Linearity

±0.16% of F.S.
(When used under
1000 to 3500 mm)*3

Repeatability

100 µm*4

Sampling rate

0.33/1/2/5 ms (Variable to 4 levels)

Operation status indicators

Laser emission warning indicator: green LED, Analog range indicator: orange LED, Reference distance indicator: red/green LED

Temperature characteristics

0.016% of F.S./°C*5

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 10,000 lux*6

Ambient temperature

-10 to +50 °C (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 350 g

*1 Amplifiers purchased before August 8th, 2012 cannot be used.
*2 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA (CDRH) Laser Notice No. 50.
*3 Value when measuring the KEYENCE standard target (white diffuse object). F.S. for each model is as follows: IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm
*4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 16. For the IL-300/IL-600, the sampling rate is 2 ms.
*5 F.S. for each model is as follows: IL-030: ±5 mm IL-065: ±10 mm IL-100: ±20 mm IL-300: ±140 mm IL-600: ±400 mm
*6 Value when the sampling rate is set to 2 ms or 5 ms.

Data Sheet (PDF) Other Models