Separate Amplifier Model, Amplifier Units Main unit (M8 Connector Type) LR-XN11C

LR-XN11C - Separate Amplifier Model, Amplifier Units Main unit (M8 Connector Type)

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • CSA

Specifications

Model

LR-XN11C

Type

NPN output/PNP output (Selectable output)

Cable/connector

M8 connector*1

Main Unit/Expansion Unit

Main Unit (expansion not possible)

No. of Control Outputs

2*2

No. of External Inputs

1*2

Response Time

500 μs*3/1 ms/3 ms/10 ms/200 ms Selectable

IO-Link

Specification v1.1/COM2 (38.4 kbps)

Function

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

Input/Output

Control Output

Open collector, 30 VDC or less, N.O./N.C.
100 mA or less for 1 output; 100 mA or less in total for 2 outputs
Residual voltage NPN: 1.4 V or less (output current: 10 mA or less)/2 V or less (output current: 10 to 100 mA),
PNP: 1.6 V or less (output current: 10 mA or less)/2.2 V or less (output current: 10 to 100 mA)

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable
Short circuit current - NPN: 1 mA or less, PNP: 2 mA or less
Input time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected)

Unit Expansion

Protection Circuit

Protection against reverse power connection, protection against output overcurrent,
protection against output surge, protection against reverse output connection

Number of Interference Prevention Devices

Power supply

Power voltage

16 to 30 VDC*4 (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 1150 mW (47 mA or less at 24 V, 64 mA or less at 16 V), ECO ON/ALL: 985 mW (40 mA or less at 24 V, 53 mA or less at 16 V) (excluding Load Current)

Environmental resistance

Ambient temperature

−20 to +55°C (no freezing)*5

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 (50G); 3 times each for X, Y, and Z axes

Case Material

Main Unit and Cover: Polycarbonate

Accessories

Instruction manual

Weight

Approx. 22 g

*1 Ensure the cable length is 30 m or less for the M8 connector type. Ensure the cable length is 20 m or less when connecting via IO-Link.
*2 Output 2 and the external input are selectable.
*3 If 500 μs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
· The interference prevention function is not supported
*4 When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.
*5 Expansion by 1 or 2 units: −20 to +55°C; Expansion by 3 to 10 units: -20 to +50°C, Expansion by 11 to 16 units: -20 to +45°C

Data Sheet (PDF) Other Models