          IX-360

          Sensor Head 360 mm

          SPECIFICATIONS

          Select Language

          Model

          IX-360

          Reference distance

          360 mm

          Measuring distance

          280 to 440 mm

          Detection area

          Scan mode

          Measuring distance of 280 mm: 66.0 × 49.5 mm (min.)
          Measuring distance of 360 mm: 84.0 × 63.0 mm (min.)
          Measuring distance of 440 mm: 102.0 × 76.5 mm
          (X direction) × (Y direction) *1

          Line mode

          Measuring distance of 280 mm: 66.0 mm (min.)
          Measuring distance of 360 mm: 84.0 mm (min.)
          Measuring distance of 440 mm: 102.0 mm
          (X direction) *1

          Laser Light source

          Light source

          660 nm (visible light) wavelength red semiconductor laser

          Laser class

          Class II laser product (FDA [CDRH] part 1040.10), Class 2 laser product (IEC 60825-1: 2014)

          Output

          0.95 mW (FDA (CDRH) Part 1040.10), 1.6 mW (IEC 60825-1: 2014)

          Minimum detectable object size

          Scan mode

          ø1.8 mm*2

          Line mode

          1.8 mm × 1.8 mm*2

          Repeatability

          150 µm*3

          Estimated detection

          (Estimated detection: When measuring the height between two points, the minimum step difference is as follows.
          IX-055: 100 µm / IX-080: 200 µm / IX-150: 500 µm / IX-360: 1000 µm) *3

          Sampling cycle

          Scan mode

          120 ms (min.) (typical)

          Line mode

          6 ms / 11 ms (selectable)

          Image receiving element

          Monochrome CMOS image sensor

          Image capture lighting

          Light source

          Red LED

          Lighting method

          Pulse lighting

          Temperature characteristics

          0.08% of F.S./°C*4

          Environmental resistance

          Enclosure rating

          IP67

          Ambient light

          Incandescent lamp, 5000 lux or less*5

          Operating ambient temperature

          0 to +45°C (No freezing) *6

          Operating ambient humidity

          35 to 85% RH (No condensation)

          Vibration resistance

          10 to 55 Hz; double amplitude 1.5 mm; 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the 3 directions

          Material

          Main unit case: Zinc die-casting / Front cover: Glass, acrylic (hard coat) /
          Operation indicator cover: TPU / Connector ring: PBT / Connector Zinc die-casting

          Weight

          Approx. 190 g

          *1 X: Long-side direction of laser, Y: Short-side direction of laser
          *2 With a correctly attached reference distance. When measuring using the height tool, measurement point min., and no position adjustment in scan mode. When measuring using the height tool, tool window size min., and no position adjustment in line mode.
          *3 When measuring at the centre of the field of view in scan mode using the “Max.” measurement point of a KEYENCE reference target (white diffuser) at the reference distance.
          *4 At the reference distance from the target. The F.S. for each model are as follows. IX-055: ±10 mm, IX-080: ±18 mm, IX-150: ±50 mm, IX-360: ±80 mm
          *5 Using the default settings with a laser light source as the target.
          *6 With metal mounting.