SJ-E series
|
Model |
SJ-E036L |
SJ-E060L |
SJ-E084L |
SJ-E108L |
SJ-E132L |
SJ-E156L |
SJ-E180L |
SJ-E204L |
SJ-E228L |
SJ-E252L |
SJ-E300L |
|||
|
Ion generation method |
Corona discharge method |
|||||||||||||
|
Structure |
Shockless resistor connection type |
|||||||||||||
|
Voltage application method/ |
Pulse AC method/±8,000 V |
|||||||||||||
|
Ion balance control method |
Hi-Power I.C.C. method |
|||||||||||||
|
Ion balance |
±30 V |
|||||||||||||
|
Operating distance |
50 to 2,000 mm |
|||||||||||||
|
Control input |
Static elimination stop input |
NPN open-collector or no-voltage contact signal |
||||||||||||
|
Control output |
Ion level alarm |
NPN open-collector, 1 00 mA max. (40 VDC or less) |
||||||||||||
|
Condition alarm |
||||||||||||||
|
Alarm output |
||||||||||||||
|
Communication feature |
Remote control communication |
|||||||||||||
|
Major features |
Condition alarm, ion level alarm, and alarm output |
|||||||||||||
|
Air connection port |
Rc 1/8 |
|||||||||||||
|
Air supply pressure |
0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1 |
|||||||||||||
|
Effective length |
440 mm*2 |
680 mm*2 |
920 mm*2 |
1,160 mm*2 |
1,400 mm*2 |
1,640 mm*2 |
1,880 mm*2 |
2,120 mm*2 |
2,360 mm*2 |
2,600 mm*2 |
||||
|
Total length |
350 mm |
560 mm |
800 mm |
1,040 mm |
1,280 mm |
1,520 mm |
1,760 mm |
2,000 mm |
2,240 mm |
2,480 mm |
||||
|
No. of electrodes |
5 |
9 |
13 |
17 |
21 |
25 |
29 |
33 |
37 |
41 |
||||
|
Rating |
Power voltage |
24 to 36 VDC ±10 % |
||||||||||||
|
Current consumption |
700 mA (at 24 V) or 500 mA (at 36 V) |
|||||||||||||
|
Overvoltage category |
I |
|||||||||||||
|
Pollution degree |
2 |
|||||||||||||
|
Environmental resistance |
Ambient temperature |
0 to +40 °C |
||||||||||||
|
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||||||||
|
Material |
Electrode probe |
Tungsten |
||||||||||||
|
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||||||||
|
Weight |
670 g |
850 g |
1,070 g |
1,270 g |
1,500 g |
1,700 g |
1,900 g |
2,100 g |
2,300 g |
2,500 g |
||||
|
*1 Contact us for details on this value when the air supply is opened and closed. |
||||||||||||||
|
Model |
SJ-E036H |
SJ-E060H |
SJ-E084H |
SJ-E108H |
SJ-E132H |
SJ-E156H |
SJ-E180H |
SJ-E204H |
SJ-E228H |
SJ-E252H |
SJ-E300H |
|||
|
Ion generation method |
Corona discharge method |
|||||||||||||
|
Structure |
Shockless resistor connection type |
|||||||||||||
|
Voltage application method/ |
Pulse AC method/±8,000 V |
|||||||||||||
|
Ion balance control method |
Hi-Power I.C.C. method |
|||||||||||||
|
Ion balance |
±30 V |
|||||||||||||
|
Operating distance |
50 to 2,000 mm |
|||||||||||||
|
Control input |
Static elimination stop input |
NPN open-collector or no-voltage contact signal |
||||||||||||
|
Control output |
Ion level alarm |
NPN open-collector, 1 00 mA max. (40 VDC or less) |
||||||||||||
|
Condition alarm |
||||||||||||||
|
Alarm output |
||||||||||||||
|
Communication feature |
Remote control communication |
|||||||||||||
|
Major features |
Condition alarm, ion level alarm, and alarm output |
|||||||||||||
|
Air connection port |
Rc 1/8 |
|||||||||||||
|
Air supply pressure |
0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1 |
|||||||||||||
|
Effective length |
420 mm*2 |
660 mm*2 |
900 mm*2 |
1,140 mm*2 |
1,380 mm*2 |
1,620 mm*2 |
1,860 mm*2 |
2,100 mm*2 |
2,340 mm*2 |
2,580 mm*2 |
3,060 mm*2 |
|||
|
Total length |
350 mm |
560 mm |
800 mm |
1,040 mm |
1,280 mm |
1,520 mm |
1,760 mm |
2,000 mm |
2,240 mm |
2,480 mm |
2,960 mm |
|||
|
No. of electrodes |
9 |
17 |
25 |
33 |
41 |
49 |
57 |
65 |
73 |
81 |
97 |
|||
|
Rating |
Power voltage |
24 to 36 VDC ±10 % |
||||||||||||
|
Current consumption |
700 mA (at 24 V) or 500 mA (at 36 V) |
|||||||||||||
|
Overvoltage category |
I |
|||||||||||||
|
Pollution degree |
2 |
|||||||||||||
|
Environmental resistance |
Ambient temperature |
0 to +40 °C |
||||||||||||
|
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||||||||
|
Material |
Electrode probe |
Tungsten |
||||||||||||
|
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||||||||
|
Weight |
680 g |
870 g |
1,100 g |
1,300 g |
1,550 g |
1,750 g |
1,950 g |
2,150 g |
2,350 g |
2,600 g |
3,000 g |
|||
|
*1 Contact us for details on this value when the air supply is opened and closed. |
||||||||||||||
|
Model |
SJ-E036A |
SJ-E060A |
SJ-E084A |
SJ-E108A |
SJ-E132A |
SJ-E156A |
SJ-E180A |
SJ-E204A |
SJ-E228A |
SJ-E252A |
SJ-E300A |
|||
|
Ion generation method |
Corona discharge method |
|||||||||||||
|
Structure |
Shockless resistor connection type |
|||||||||||||
|
Voltage application method/ |
Pulse AC method/±8,000 V |
|||||||||||||
|
Ion balance control method |
Hi-Power I.C.C. method |
|||||||||||||
|
Ion balance |
±30 V |
|||||||||||||
|
Operating distance |
50 to 2,000 mm |
|||||||||||||
|
Control input |
Static elimination stop input |
NPN open-collector or no-voltage contact signal |
||||||||||||
|
Control output |
Ion level alarm |
NPN open-collector, 1 00 mA max. (40 VDC or less) |
||||||||||||
|
Condition alarm |
||||||||||||||
|
Alarm output |
||||||||||||||
|
Major features |
Condition alarm, ion level alarm, and alarm output |
|||||||||||||
|
Air connection port |
Rc 1/8 |
|||||||||||||
|
Air supply pressure |
0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1 |
|||||||||||||
|
Effective length |
420 mm*2 |
660 mm*2 |
900 mm*2 |
1,140 mm*2 |
1,380 mm*2 |
1,620 mm*2 |
1,860 mm*2 |
2,100 mm*2 |
2,340 mm*2 |
2,580 mm*2 |
3,060 mm*2 |
|||
|
Total length |
350 mm |
560 mm |
800 mm |
1,040 mm |
1,280 mm |
1,520 mm |
1,760 mm |
2,000 mm |
2,240 mm |
2,480 mm |
2,960 mm |
|||
|
No. of electrodes |
5 |
9 |
13 |
17 |
21 |
25 |
29 |
33 |
37 |
41 |
49 |
|||
|
Rating |
Power voltage |
24 to 36 VDC ±10 % |
||||||||||||
|
Current consumption |
700 mA (at 24 V) or 500 mA (at 36 V) |
|||||||||||||
|
Overvoltage category |
I |
|||||||||||||
|
Pollution degree |
2 |
|||||||||||||
|
Environmental resistance |
Ambient temperature |
0 to +40 °C |
||||||||||||
|
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||||||||
|
Material |
Electrode probe |
Tungsten |
||||||||||||
|
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||||||||
|
Weight |
670 g |
850 g |
1,070 g |
1,270 g |
1,500 g |
1,700 g |
1,900 g |
2,100 g |
2,300 g |
2,500 g |
2,900 g |
|||
|
*1 Contact us for details on this value when the air supply is opened and closed. |
||||||||||||||
|
Model |
SJ-E060N |
|||
|
Ion generation method |
Corona discharge method |
|||
|
Structure |
Shockless resistor connection type |
|||
|
Voltage application method/ |
Pulse AC method/±8,000 V |
|||
|
Ion balance control method |
Hi-Power I.C.C. method |
|||
|
Ion balance |
±30 V |
|||
|
Operating distance |
50 to 2,000 mm |
|||
|
Communication feature |
RS-485 communication/remote control communication |
|||
|
Major features |
Condition alarm, ion level alarm, and alarm output |
|||
|
Air connection port |
Rc 1/8 |
|||
|
Air supply pressure |
0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*1 |
|||
|
Effective length |
680 mm*2 |
|||
|
Total length |
560 mm |
|||
|
No. of electrodes |
9 |
|||
|
Rating |
Power voltage |
24 to 36 VDC ±10 % |
||
|
Current consumption |
700 mA (at 24 V) or 500 mA (at 36 V) |
|||
|
Overvoltage category |
I |
|||
|
Pollution degree |
2 |
|||
|
Environmental resistance |
Ambient temperature |
0 to +40 °C |
||
|
Relative humidity |
35 to 85 % RH (No condensation) |
|||
|
Material |
Electrode probe |
Tungsten |
||
|
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
|
Weight |
850 g |
|||
|
*1 Contact us for details on this value when the air supply is opened and closed. |
||||
Downloads