SJ-F2000/5000 series
|
Model |
SJ-F2500 |
SJ-F5500 |
|||
|
Type |
300 mm type |
600 mm type |
|||
|
Voltage application method |
Pulse AC method |
||||
|
Applied voltage |
±7000V |
||||
|
Ion balance control method |
I.C.C. |
||||
|
Ion balance |
±5 V*1 |
||||
|
Static elimination time |
Approx. 0.6 sec*2 |
||||
|
Operating distance |
50 mm min. |
||||
|
Maximum wind speed |
5.7 m/s*1 |
||||
|
Maximum air volume |
4.0 m3/min |
10.0 m3/min |
|||
|
Ozone density |
0.005 ppm max. |
||||
|
Power source input type |
KEYENCE AC Adaptor or |
AC cord input |
|||
|
Rating |
Power voltage |
24 VDC ±10 % |
100 to 240 VAC, 50/60 Hz |
||
|
Current consumption |
1.2 A |
||||
|
Power consumption |
90 VA |
||||
|
Environmental resistance |
Pollution degree |
2 |
|||
|
Overvoltage category |
II |
||||
|
Ambient temperature |
0 to +50 °C |
||||
|
Relative humidity |
35 to 65 % RH |
||||
|
Weight |
Approx. 2 kg |
Approx. 5 kg |
|||
|
*1 Measured at a distance of 300 mm from the front of the fan |
|||||
|
Model |
SJ-F2000 |
SJ-F5000 |
SJ-F2010 |
SJ-F5010 |
|||
|
Type |
300 mm type |
600 mm type |
300 mm type |
600 mm type |
|||
|
Voltage application method |
Pulse AC method |
||||||
|
Applied voltage |
±7000V |
||||||
|
Ion balance control method |
I.C.C. |
||||||
|
Ion balance |
±5 V*1 |
||||||
|
Static elimination time |
Approx. 1 sec*2 |
||||||
|
Operating distance |
50 mm min. |
||||||
|
Maximum wind speed |
3.5 m/s*1 |
||||||
|
Maximum air volume |
2.5 m3/min |
6.2 m3/min |
2.5 m3/min |
6.2 m3/min |
|||
|
Ozone density |
0.005 ppm max. |
||||||
|
Power source input type |
KEYENCE AC Adaptor or DC option |
AC cord input |
Terminal block DC input |
||||
|
Control input |
Static elimination stop input |
― |
24 VDC input |
||||
|
Control output |
Alarm/ Ion level alert/ Condition alert |
NPN open-collector |
100 mA (40 V max.) |
||||
|
PNP open-collector |
100 mA (24 V ±10%) |
||||||
|
Rating |
Power voltage |
24 VDC ±10 % |
100 to 240 VAC, 50/60 Hz |
24 VDC ±10 % |
|||
|
Current consumption |
0.9 A |
1.0 A |
1.9 A |
||||
|
Power consumption |
65 VA |
||||||
|
Environmental resistance |
Pollution degree |
2 |
|||||
|
Overvoltage category |
II |
||||||
|
Ambient temperature |
0 to +50 °C |
||||||
|
Relative humidity |
35 to 65 % RH |
||||||
|
Weight |
Approx. 2 kg |
Approx. 5 kg |
Approx. 2 kg |
Approx. 4 kg |
|||
|
*1 Measured at a distance of 300 mm from the front of the fan |
|||||||
|
Model |
SJ-U2 |
|||
|
Rating |
Rating input |
100 to 240 VAC (50/60 Hz) |
||
|
Rated output |
24 VDC 2.65 A |
|||
|
Environmental resistance |
Ambient temperature |
0 to +35 °C |
||
|
Relative humidity |
20 to 80 % RH (No condensation) |
|||
|
Weight |
Approx. 250 g |
|||
Downloads
For Your Support