High-speed Clean Air Barrier Static Eliminator
SJ-G series
Recommended Replaceable Products: High-Accuracy High-Speed Sensing Ionizer - SJ-Q series
Contact Us: +32 (0) 15 281 222 Enquiry form
Bar Type Main Unit 1320 mm SJ-G132
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | SJ-G132*1  | |||
Ion generation method  | Corona discharge method  | |||
Structure  | Shockless resistor connection type  | |||
Voltage application method/Applied voltage  | Pulse AC method/±7,000 V  | |||
Ion balance control method  | I.C.C. method  | |||
Ion balance  | ±30 V*2*3  | |||
Operating distance  | 50 to 2,000 mm  | |||
Control input  | NPN open-collector or no-voltage contact signal  | |||
Control output  | NPN type photo relay, 100 mA max. (40 V max.)  | |||
Major applications  | Alarm output, Ion level alarm output, condition alarm output,  | |||
Air purge connection port  | M5  | |||
Air purge supplied pressure  | 0.2 MPa or less  | |||
Rating  | Power voltage  | 24 to 36 VDC ±10 %  | ||
Over-voltage category  | I  | |||
Pollution degree  | 2  | |||
Current consumption  | 250 mA (at 24 VDC)/150 mA (at 36 VDC)  | |||
Environmental resistance  | Ambient temperature  | 0 to +50 °C  | ||
Relative humidity  | 35 to 85 % RH (No condensation)  | |||
Material  | Electrode probe  | Tungsten  | ||
Electrode  | Stainless steel  | |||
Main unit  | ABS resin  | |||
Weight  | Controller  | ―  | ||
Bar  | Approx 1,350 g  | |||
*1 A 10-pin I/O cable or a 10-to-10 pin modular cable is required for connection.  | ||||