High-Accuracy High-Speed Sensing Ionizer
SJ-Q series
Specs High-Accuracy High-Speed Sensing Ionizer SJ-Q series
|
Model |
SJ-Q036 |
SJ-Q060 |
SJ-Q084 |
SJ-Q108 |
SJ-Q132 |
|||
|
Image |
|
|
|
|
|
|||
|
Ion generation method |
Corona discharge method |
|||||||
|
Structure |
Shockless resistive coupling type |
|||||||
|
Voltage application method/ |
Pulse AC method/±8000 Vmax |
|||||||
|
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
|
Ion balance |
±3 V *1 |
|||||||
|
Clean rating |
ISO14644-1 Class 3 *2 |
|||||||
|
Operating distance |
10 mm or more |
|||||||
|
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||||||
|
Control output |
Ion level alarm |
NPN open collector |
||||||
|
Condition alarm |
||||||||
|
Alarm output |
||||||||
|
Communication functions |
Remote control |
|||||||
|
Average power consumption |
Normal operation: 8.4 W, |
|||||||
|
Major features |
Condition alarm, ion level alarm, alarm output |
|||||||
|
Air connection port |
Rc1/8 |
|||||||
|
Air supply pressure |
0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*4 |
|||||||
|
Effective length |
440 mm *5 |
680 mm *5 |
920 mm *5 |
1160 mm *5 |
1400 mm *5 |
|||
|
Total length |
350 mm |
560 mm |
800 mm |
1040 mm |
1280 mm |
|||
|
No. of electrodes |
5 |
9 |
13 |
17 |
21 |
|||
|
Rating |
Power voltage |
24 to 36 VDC±10% |
||||||
|
Current consumption |
Normal operation: 700 mA or less, |
|||||||
|
Overvoltage category |
I |
|||||||
|
Pollution degree |
2 |
|||||||
|
Environmental resistance |
Ambient temperature |
0 to +40°C |
||||||
|
Relative humidity |
85% RH or less (no condensation) |
|||||||
|
Material |
Electrode probe |
Tungsten |
||||||
|
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
|
Weight |
690 g |
890 g |
1120 g |
1340 g |
1580 g |
|||
|
*1 Measured under the following conditions. |
||||||||
|
Model |
SJ-Q156 |
SJ-Q180 |
SJ-Q204 |
SJ-Q228 |
SJ-Q252 |
SJ-Q300 |
|||
|
Image |
|
|
|
|
|
|
|||
|
Ion generation method |
Corona discharge method |
||||||||
|
Structure |
Shockless resistive coupling type |
||||||||
|
Voltage application method/ |
Pulse AC method/±8000 Vmax |
||||||||
|
Ion balance control method |
Hi-Power I.C.C. method |
||||||||
|
Ion balance |
±3 V *1 |
||||||||
|
Clean rating |
ISO14644-1 Class 3 *2 |
||||||||
|
Operating distance |
10 mm or more |
||||||||
|
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
|||||||
|
Control output |
Ion level alarm |
NPN open collector |
|||||||
|
Condition alarm |
|||||||||
|
Alarm output |
|||||||||
|
Communication functions |
Remote control |
||||||||
|
Average power consumption |
Normal operation: 8.4 W, |
||||||||
|
Major features |
Condition alarm, ion level alarm, alarm output |
||||||||
|
Air connection port |
Rc1/8 |
||||||||
|
Air supply pressure |
0.1 to 0.5 MPa (recommended air pressure: 0.2 MPa)*4 |
||||||||
|
Effective length |
1640 mm *5 |
1880 mm *5 |
2120 mm *5 |
2360 mm *5 |
2600 mm *5 |
3080 mm *5 |
|||
|
Total length |
1520 mm |
1760 mm |
2000 mm |
2240 mm |
2480 mm |
2960 mm |
|||
|
No. of electrodes |
25 |
29 |
33 |
37 |
41 |
49 |
|||
|
Rating |
Power voltage |
24 to 36 VDC±10% |
|||||||
|
Current consumption |
Normal operation: 700 mA or less, |
||||||||
|
Overvoltage category |
I |
||||||||
|
Pollution degree |
2 |
||||||||
|
Environmental resistance |
Ambient temperature |
0 to +40°C |
|||||||
|
Relative humidity |
85% RH or less (no condensation) |
||||||||
|
Material |
Electrode probe |
Tungsten |
|||||||
|
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
||||||||
|
Weight |
1800 g |
2010 g |
2230 g |
2440 g |
2660 g |
3090 g |
|||
|
*1 Measured under the following conditions. |
|||||||||